KP-100 Sea Cooler at a glance
The KP-100 Sea Cooler capacity is up to 9.100 liters per hour of seawater that is cooled to -2°C. The salt content must be 2.6% NaCl minimum. If needed salinity is not available, brine systems can be utilized Sea usage at 15°C is up to 6.000 liters per hour and sea filtration is 100 micron.
Sea Coolers from Kæling ehf. are of the highest quality and designed as a cost-effective alternative to modern refrigeration technology to maximize catch value. Sea Coolers can be used in many stages of food processing, both at sea and on land.
Cooled seawater is extremely suitable for ensuring the correct temperature of the catch at all stages from the time it is hauled on board until storage cooling begins. Sea Coolers can offer extraction of different temperature cooled sea for each processing stage.
This way you can have perfect cooling on everyone levels and maximize catch quality. Proper cooling slows down the growth of bacteria and reduces the activity of enzymes.
The surface temperature of the sea is often higher than the sea temperature at the level which the catch is coming from. Therefore, pumped seawater directly from the surface can accelerate loss
of freshness. Sea temperatures can vary greatly depending on
the season, which affects the capacity of Sea Coolers. Advanced Control Unit with electronic sensors and valves enable accurate flow of seawater through the Sea Cooler at the perfect temperature for the process.
The KP-100 Sea Cooler capacity is up to 9.100 liters per hour of seawater that is cooled to -2°C. The salt content must be 2.6% NaCl minimum. If needed salinity is not available, brine systems can be utilized Sea usage at 15°C is up to 6.000 liters per hour and sea filtration is 100 micron.
Sea Coolers from Kæling ehf. have cooling compressors that run on 3 phases electricity, condenser, titanium heat exchanger and computer-controlled control valves. A control panel with a touch screen can be placed almost anywhere and possible to have more than one control displays for each sea cooler.
In order to maintain full capacity of a slurry ice machine the sea water temperature needs to be 0°. There for it is common to install both a Sea Cooler and a Slurry Ice Machine.
It is our goal to deliver top quality solutions and there for we choose to use the best available equipment and materials for Sea Coolers and all our products. One of these choices is that we always use a titanium plate heat exchanger which significantly increases both performance and durability. With regular service inspection and proper maintenance, the live time of the machines can be expected up to 25 years or even longer.
Power consumption 3×230 / 400 V: | 35 kW |
Cooler capicity: | 100 kW |
Cooling capicity at 10°C to -2°C: | 9.1000 l/klst. |
Minimum salinity: | 2,6% NaCI |
Measurements in mm LxWxH: | 2200x700x1700 |
Weight: | 786 kg |
Refrigerant: | 404A/449A |
Sea filter: | 100 my |
Sea usage at 15°: | 6.000 l/klst. |
Please contact us for further information.
Kæling ehf. is a leading company in the field of comprehensive cooling solutions for the fishing industry. We are constantly working on enabling our customers to maximize their catch value with expert cooling at all levels. Cooling solutions from Kæling have gained a foothold both in Iceland and abroad, as they have stood the test of time for quality, reliability, performance, durability and good service.